| Category |
Credit |
Intent |
How KONE Contributes? |
 |
EAc1: Optimize Energy Performance |
To achieve increasing levels of energy performance beyond the prerequisite standard to reduce environmental and economic impacts associated with excessive energy use |
Through using the “Exceptional Calculation Method” the project team can document measures that reduce process loads (elevators / escalators) such as MRL vs.hydros. KONE can provide this documentation using an energy calculation tool. |
|

|
MRc3: Materials Reuse |
To reuse building materials and products to reduce demand for virgin materials and reduce waste, thereby lessening impacts associated with the extraction and processing of virgin resources. |
Elevators / Escalators are specifically excluded from this credit. |
| MRc4: Recycled Content |
To increase demand for building products that incorporate recycled content materials, thereby reducing impacts resulting from extraction and processing of virgin materials. |
Elevators / Escalators are specifically excluded from this credit. |
| MRc5: Regional Materials |
To increase demand for building materials and products that are extracted and manufactured within the region, thereby supporting the use of indigenous resources and reducing the environmental impacts resulting from transportation. |
Elevators / Escalators are specifically excluded from this credit. |
| MRc6: Rapidly Renewable Materials |
To reduce the use and depletion of finite raw materials and long-cycle renewable materials by replacing them with rapidly renewable materials. |
KONE Elevators & Escalators do not contain Rapidly Renewable materials. |
| MRc7: Certified Wood |
To encourage environmentally responsible forest management. |
KONE’s raised wood panels are FSC certified. |
|

|
IEQc4.1: Low-Emitting Materials - Adhesives & Sealants |
To reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well-being of installers and occupants. |
KONE's installation methods do not apply adhesives or sealants on-site. All adhesives & sealants are applied in the manufacturing process. Therefore, this credit does not apply. |
| IEQc4.2: Low-Emitting Materials - Paints & Coatings |
To reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well-being of installers and occupants. |
KONE's installation methods do not apply paints & coatings on-site. All paints & coatings are applied in the manufacturing process. Therefore, this credit does not apply. |
| IEQ4.3: Low-Emitting Materials - Flooring Systems |
To reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well-being of installers and occupants. |
KONE does not supply the flooring for installation and therefore, this credit does not apply. |
| IEQ4.4: Low-Emitting Materials - Composite Wood & Agrifiber Products |
To reduce the quantity of indoor air contaminants that are odorous, irritating and/or harmful to the comfort and well-being of installers and occupants. |
KONE meets this requirement by providing urea-formaldehyde free raised wood panels as the standard offering. |
 |
IDc1: Innovation in Design |
Provide design teams and projects the opportunity to achieve exceptional performance above the requirements and/or innovative performance in categories not specifically addressed by LEED. |
Projects installing a Machine Room-Less elevator can achieve an ID credit through showing Process Energy Savings for Elevators. KONE can provide supporting documentation such as a carbon footprint assessment, energy calculations, calculations for the elimination of hydraulic oil etc... |